Contact Us
 
Product Literature Order Form Credit Application FAQ About Us Contact Us
Filters: Carbon Block KX
Standard size carbon block filters for filtering based on micron size of particles
MATRIKX® +1 - "The Chlorine Guzzler"
MATRIKX® +1 - "The Chlorine Guzzler"
High Chlorine Removal and High VOC Reduction Capacity
View Larger Image
NSF Certified
Item NumberModel #ChlorineMicronFlow RateDimensions 
01250125975 01-250-125-97520,0000.60.5 gpm2.5" x 9.75" 
0125012520 01-250-125-2045,0000.61.2 gpm2.5" x 20" 
01425125975 01-425-125-97570,0000.61.5 gpm4.25" x 9.75" 
0142512520 01-425-125-20150,0000.63.5 gpm4.25" x 20" 
Tested and Certified by NSF Intl. under NSF/ANSI Standard 42 for material requirements only.


MATRIKX® +5 -"A Sweeter Taste"
MATRIKX® +5 -"A Sweeter Taste"
Coconut Shell Based, High Chemical Absorptive Capacity, including VOC and TOC
View Larger Image
NSF Certified
Item NumberModel #ChlorineMicronFlow RateDimensions 
02250125975 02-250-125-9756,00021 gpm2.5" x 9.75" 
0225012520 02-250-125-2015,00022.3 gpm2.5" x 20" 
02425125975 02-425-125-97520,00023 gpm4.25" x 9.75" 
0242512520 02-425-125-2042,00027 gpm4.25" x 20" 
Tested and Certified by NSF Intl. under NSF/ANSI Standard 42 for material requirements only.


MATRIKX® 10/2 - "The Only Choice"
MATRIKX® 10/2 - "The Only Choice"
High Performance at Low Cost, Out-performs GAC/PAC Filters
View Larger Image
NSF Certified
Item NumberModel #ChlorineMicronFlow RateDimensions 
10250190975 10-250-190-9756,00031 gpm2.5" x 9.75" 
1025019020 10-250-190-2012,00032 gpm2.5" x 20" 
Tested and Certified by NSF Intl. under NSF/ANSI Standard 42 for material requirements only.


MATRIKX® +CTO®/2 - "The Workhorse"
MATRIKX® +CTO®/2 - "The Workhorse"
Most Widely Used Carbon Block Devices in the World
View Larger Image
NSF Certified
Item NumberModel #ChlorineMicronFlow RateDimensions 
32250125050 32-250-125-0501,75050.5 gpm2.5" x 5" 
32250125975 32-250-125-9756,00051 gpm2.5" x 9.75" 
3225012520 32-250-125-2012,00052 gpm2.5" x 20" 
32425125975 32-425-125-97512,00053 gpm4.25" x 9.75" 
3242512520 32-425-125-2026,00057 gpm4.25" x 20" 
Tested and Certified by NSF Intl. under NSF/ANSI Standard 42 for material requirements only.


MATRIKX® CR1 - "Chlorine & Cyst Reduction"
MATRIKX® CR1 - "Chlorine & Cyst Reduction"
Meets NSF Standard 53 for Class 1 Turbidity & Cyst Reduction, including Giardia & Cryptosporidium
View Larger Image
NSF Certified
Item NumberModel #ChlorineMicronFlow RateDimensions 
19250125975 19-250-125-97510,0000.52.5 gpm2.5" x 9.75" 
1925012520 19-250-125-2020,0000.55 gpm2.5" x 20" 
Tested and Certified by NSF Intl. under NSF/ANSI Standard 42 for material requirements only.


MATRIKX® Pb1 - "The Premier Performer"
MATRIKX® Pb1 - "The Premier Performer"
Lead, Cyst, and Class 1 Turbidity Reduction - 0.5 Micron Rating
View Larger Image
NSF Certified
Item NumberModel #ChlorineLeadFlow RateDimensions 
06250125975 06-250-125-9756,0002,5000.75 gpm2.5" x 9.75" 
0625012520 06-250-125-2012,0005,0001.5 gpm2.5" x 20" 
06425200975 06-425-200-97520,0008,0002.5 gpm4.25" x 9.75" 
0642520020 06-425-200-2042,00017,0005 gpm4.25" x 20" 
Tested and Certified by NSF Intl. under NSF/ANSI Standard 42 for material requirements only.


CERAMIKX® - "All Carbon, Sub-Micron Performance"
CERAMIKX® - "All Carbon, Sub-Micron Performance"
99.9996% Reduction of E. coli and Meets NSF 42 Class 1
View Larger Image
NSF Certified
Item NumberModel #ChlorineMicronFlow RateDimensions 
20185125083 20-185-125-0831,0000.20.5 gpm1.85" x 9.75" 
20250190975 20-250-190-9752,0000.20.75 gpm2.5" x 9.75" 


PLEKX® -"Spiral Wound Carbon and Sediment Filter"
PLEKX® -"Spiral Wound Carbon and Sediment Filter"
High Dirt Holding Capacity
View Larger Image
NSF Certified
Item NumberModel #ChlorineMicronDimensionsDescription 
P10250109096 P10-250-109-0962,50052.5" x 9.75"Plekx 10 - Non-Cellulose 
PC236109096 PC-236-109-0960202.5" x 9.75"PC2 Pleated Cellulose 
Note: Capacity based on 1 gpm flow rate. Chlorine capacity is the estimated capacity in gallons during which the filter will remove >95% of influent free available chlorine (2 ppm) when operating at a given flow and has been tested using the NSF standard


Contact Us | Press Center | Site Map | Homepage

Visit the WQA 
2008 G.A. Murdock Inc. All rights reserved.      Copyright & Trademark    Privacy Statement

Translate with